10 technical data, 1 technical data - electrical ratings, 2 technical data - mechanical design – Baumer HOG 11 Benutzerhandbuch

Seite 29: Technical data, Technical data - electrical ratings, Technical data - mechanical design

Advertising
background image

MB072a - 11070667

Baumer_HOG11-R_II_DE-EN (14A2)

26

Technical data

10

* The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution

10

Technical data

10.1

Technical data - electrical ratings
• Voltage supply:

9...30 VDC* (HTL-P, TTL - version R)

5 VDC ±5 % (TTL)

• Consumption w/o load:

≤100 mA

• Pulses per revolution:

300...5000 (As ordered)

• Phase shift:

90° ±20°

• Scan ratio:

40...60 %

• Reference signal:

Zero pulse, width 90°

• Sensing method:

Optical

• Output frequency:

≤120 kHz

≤300 option

• Output signals:

K1, K2, K0 + inverted

Error output (only EMS)

• Output stages:

HTL-P (power linedriver)

TTL/RS422

(As ordered)

• Interference immunity:

EN 61000-6-2:2005

• Emitted interference:

EN 61000-6-3:2007/A1:2011

• Approvals:

CE, UL approval / E256710

10.2

Technical data - mechanical design
• Size (flange):

ø105 mm

• Shaft type:

ø12...20 mm (blind hollow shaft)

ø17 mm (cone shaft 1:10)

• Shaft loading:

≤450 N axial; ≤600 N radial

• Protection DIN EN 60529:

IP67

• Operating speed:

≤6000 rpm (mechanical)

• Operating torque typ.:

6 Ncm

• Rotor moment of inertia:

340 gcm

2

• Materials:

Housing: aluminium die-cast

Shaft: stainless steel

• Operating temperature:

-40…+100 °C

-25...+100 °C (>3072 pulses per revolution)

-50...+100 °C (optional with internal heating)

Restricted in potentially explosive environments, see section 2.

• Resistance:

IEC 60068-2-6:2007

Vibration 20 g, 10-2000 Hz

IEC 60068-2-27:2008

Shock 300 g, 6 ms

• Explosion protection:

II 3 G Ex nA IIC T4 Gc (gas)

II 3 D Ex tc IIIC T135°C Dc (dust)

• Connection:

Terminal cover

• Weight approx.:

1.6 kg

Advertising