10 technical data, 1 technical data - electrical ratings, 2 technical data - mechanical design – Baumer HOG 9 G Benutzerhandbuch
Seite 33: Technical data, Technical data - electrical ratings, Technical data - mechanical design

MB004T1 - 11068581
Baumer_HOG9-HOG9G-T1_II_DE-EN (14A3)
30
Technical data
10
10
Technical data
10.1
Technical data - electrical ratings
• Voltage supply:
9...30 VDC* (HTL-P, TTL - version R)
5 VDC ± 5 % (TTL)
• Consumption w/o load:
≤100 mA
• Pulses per revolution:
300...5000 (As ordered)
• Phase shift:
90° ±20°
• Scan ratio:
40...60 %
• Reference signal:
Zero pulse, width 90°
• Sensing method:
Optical
• Output frequency:
≤120 kHz
≤300 kHz option
• Output signals:
K1, K2, K0 + inverted
• Output stages:
HTL-P (power linedriver); TTL/RS422
(As ordered)
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
• Approvals:
CE, UL approval / E256710
10.2
Technical data - mechanical design
• Size (flange):
ø97 mm
• Shaft type:
ø12...16 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
• Shaft loading:
≤400 N axial; ≤500 N radial
• Protection DIN EN 60529:
IP56
• Operating speed:
≤10000 rpm (mechanical)
• Operating torque typ.:
6 Ncm
• Rotor moment of inertia:
160 gcm
2
• Materials:
Housing: aluminium die-cast; Shaft: stainless steel
• Operating temperature:
-30…+100 °C
-25…+100 °C (>3072 pulses per revolution)
Restricted in potentially explosive environments, see section 2.
• Resistance:
IEC 60068-2-6:2007
Vibration 17 g, 10-2000 Hz
IEC 60068-2-27:2008
Shock 275 g, 6 ms
• Corrosion protection:
IEC 60068-2-52, salt mist
complies to ISO 12944-5:1998
protective paint systems (C4)
• Explosion protection:
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
• Connection:
Flange connector M23, 12-pin (2x with option G)
• Weight approx.:
800 g; 1.6 kg (with option G)
* The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution