Optische sensoren / photoelectric sensors – Baumer BA OADM250 Benutzerhandbuch

Seite 12

Advertising
background image

Optische Sensoren / Photoelectric Sensors


Seite 12

www.baumer.com

Outputs:

Analog output
Two sensor versions are available: with voltage output 0 … 10 V or current output 4 … 20 mA.

Alarm output (active high)
As long as there is an object within the actual - taught - measuring range and the signal received is
sufficiently strong the output is low.
If there is no object inside the actual - taught - measuring range or the signal received is of
insufficient strength or quality the alarm output is high.


Functions:

Every sensor is delivered with the factory setup (max. measuring range). The teach-in feature was
designed to choose a smaller range within the nominal measuring range for optimizing the
resolution. Output current, voltage and alarm output adapt to the new range. Two positions must be
taught.

•

The first teach-in position aligns with 0 V (or 4 mA), the second position aligns with 10 V (or 20

mA)

•

These teach-in positions are always just at the border of the new range (inside the measuring

range)

•

The sensor may be taught more than 10,000 times in its lifetime

•

The sensor can always be reset to the factory settings

•

The sensor may be taught using the teach button or via the external teach input

•

During the teach-in process, the red LED and the alarm output provides a feedback

•

The red LED on the back side of the sensor and the alarm output indicate “run” mode if an object

is within the measuring range.



Attention:
Within 5 minutes after power on, the sensor can be taught using the button or the teach-in wire.
After 5 minutes, the teach-in button will be locked preventing accidental adjustment. The teach-in
wire is active all the time.

0.2 m

4 m

4mA

2mA

Analog out

20 mA

Example of
a taught
output
curve

Alarm out

LED

Standard
output
curve

0.2 m

4 m

4mA

2mA

Analog out

20 mA

Example of a
revers taught
output curve

Alarm out

LED

Standard
output
curve

0.2 m

4 m

0 V

Analog out

10 V

Example of a
revers taught
output curve

Alarm out

LED

Standard output
curve

0.2 m

4 m

0V

Analog out

10 V

Example of a
taught output
curve

Alarm out

LED

Standard output
curve