9 technical data, 1 technical data - electrical ratings, 2 technical data - electrical ratings (encoder) – Baumer HOG 165 + DSL Benutzerhandbuch

Seite 40: Technical data, Technical data - electrical ratings, Technical data - electrical ratings (encoder)

Advertising
background image

37

Baumer_HOG165-DSL-T1_II_DE-EN (14A1)

MB104.3T1 - 11113957

9

Technical data

9

Technical data

9.1

Technical data - electrical ratings

Consumption w/o load:

≤200 mA

HOG 165 + DSL.E
Voltage supply:

9...30 VDC

HOG 165 + DSL.R
Voltage supply:

15...30 VDC

9.2

Technical data - electrical ratings (encoder)

Pulses per revolution:

512...4096 (As precised on order)

Phase shift:

90° ±20°

Duty cycle:

40...60 %

Reference signal:

Zero pulse, width 90°

Output frequency:

≤120 kHz

Output signals:

K1, K2, K0 + inverted

Output stage:

HTL

TTL/RS422

(As precised on order)

Sensing method:

Optical

9.3

Technical data - electrical ratings (speed switches)

Interface:

RS485

Switching accuracy:

±2 % (Digit)

Switching delay time:

≤40 ms

HOG 165 + DSL.E
Switching outputs:

2 outputs, speed control

1 control output

Output switching capacity:

5...230 VAC/VDC; 5...250 mA

HOG 165 + DSL.R
Switching outputs:

3 outputs, speed control

Output switching capacity:

12 VDC; ≤40 mA

Advertising