Technical data
10
10
Technical data
10.1
Technical data - electrical ratings
• Voltage supply:
9...30 VDC (HTL)
9...26 VDC (TTL - version R)
5 VDC ±5 % (TTL)
• Consumption w/o load:
≤100 mA
• Pulses per revolution:
250...2500 (As precised on order)
• Phase shift:
90° ±20°
• Scan ratio:
40...60 %
• Reference signal:
Zero pulse, width 90°
• Sensing method:
Optical
• Output frequency:
≤120 kHz
• Output signals:
K1, K2, K0 + inverted
• Output stages:
HTL
TTL/RS422
(As precised on order)
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
• Approvals:
CE, UL approval / E256710
10.2
Technical data - mechanical design
• Size (flange):
ø158 mm
• Shaft type:
ø20...38 mm (through hollow shaft)
• Shaft loading:
≤450 N axial
≤600 N radial
• Protection DIN EN 60529:
IP 66
• Operating speed:
≤6000 rpm (mechanical)
• Operating torque typ.:
15 Ncm
• Rotor moment of inertia:
4.9 kgcm
2
(ø25)
• Materials:
Housing: aluminium alloy
Shaft: stainless steel
• Operating temperature:
-20…+100 °C
• Resistance:
IEC 60068-2-6:2007
Vibration 20 g, 10-2000 Hz
IEC 60068-2-27:2008
Shock 300 g, 6 ms
• Connection:
Terminal box
2x terminal box (with option M)
• Weight approx.:
4.9 kg
5.1 kg (with option M)