Programming plan – Baumer NE230 Benutzerhandbuch
Seite 15

NE230
www.baumer.com
15
9. Programming plan
Lines
11-17
status of lines 1-7
0
parameter to be altered
1
clear resp. input lock
2
skip parameter
Line 22
operation mode
0
step preset
1
main preset
2
parallel comparison
3
P1 trailing preset
Line 24
decimal point
0
no decimal point
1
00000.0
2
0000.00
3
000.000
4
00.0000
Line 25
counting mode
0
track A UP/DOWN signal on track B
1
difference (A-B)
2
total (A+B)
3
track A 90° B single evaluation
4
track A 90° B double evaluation
5
track A 90° B four-times evaluation
Line 26
frequency main counter track A
0
10 kHz
1
25 Hz
2
3 Hz
Line 27
frequency main counter track B
0
10 kHz
1
25 Hz
2
3 Hz
Line 28
switching threshold and input logic
0
switching threshold 6V PNP
1
switching threshold 6V NPN
2
switching threshold 3V PNP
3
switching threshold 3V NPN
Line 29
main counter reset (control input 1)
0
automatic reset and externally static
1
automatic reset and externally differential
2
externally static
3
externally differential
4
externally with "start-function"
Line 31
function control input 2
0
stop
1
hold
2
keylock
3
hour counter on/off
4
offset
5
print (only with interface)
Line 33
output logic digital outputs
0
both outputs normally closed
1
P1 normally open, P2 normally closed
2
P1 normally closed, P2 normally open
3
both outputs normally open
Line 35
momentary signal time P1
0.25
default
0.01
Min.
99.99
Max.
Line 36
momentary signal time P2
0.25
default
0.01
Min.
99.99
Max.