Baumer NE230 Benutzerhandbuch
Seite 16

NE230
16 www.baumer.com
Line 37
activation of presets P1, P2
0
immediately active
1
after reset
Line 38
counting range P1,P2 and SC
0
positive only
1
positive and negative
Line 39
function key assignment
0
w/o function
1
XP
2
P1
3
P2
4
SC
5
Σ
6
Á
7
SF
Line 40
code
0000
code not active
:
9999
Line 41
batch counter function
0
totalizer
1
counting upon achieving P2
Line 42
batch counter multiplier (Line 41=1)
1
default
0
min.
999
max.
Line 43
offset
0
no offset
:
999999
max. offset value
Line 44
mains failure display
0
no mains failure display
1
mains failure display (blinking)
Line 51
Baud rate
0
4800 Baud
1
2400 Baud
2
1200 Baud
3
600 Baud
Line 52
parity
0
even parity
1
odd parity
2
no parity
Line 53
stop bits
0
1 stop bit
1
2 stop bits
Line 54
counter identification
00
default
00
min.
99
max.
Line 55
output value assignment by interface
Line 31=5
0
display value
1
XP
2
P1
3
P2
4
SC
5
Σ
6
Á
7
SF
Line 56
RS422: control connections TxD+ , TxD-
0
In sending direction during sending, in receiving direction during reception
1