Technical data
10
10
Technical data
10.1
Technical data - electrical ratings
• Voltage supply:
9...30 VDC (HTL)
5 VDC ±5 % (TTL)
9...26 VDC (TTL - R)
• Consumption w/o load:
≤100 mA
• Pulses per revolution:
250...2500 (As precised on order)
• Phase shift:
90° ±20°
• Duty cycle:
40...60 %
• Reference signal:
Zero pulse, width 90°
• Sensing method:
Optical
• Output frequency:
≤120 kHz
• Output signals:
K1, K2, K0 + inverted
• Output stage:
HTL
TTL/RS422
(As precised on order)
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
• Approvals:
CE, RoHS
10.2
Technical data - mechanical design
• Size (flange):
ø160 mm
• Shaft type:
ø30...70 mm (through hollow shaft)
(As precised on order)
• Shaft loading:
≤450 N axial
≤650 N radial
• Protection DIN EN 60529:
IP 54, IP 56
• Operating speed:
≤5600 rpm (mechanical)
• Operating torque typ.:
60 Ncm
• Rotor moment of inertia:
31.9 kgcm
2
(ø40)
11.3 kgcm
2
(ø70)
• Materials:
Housing: aluminium alloy
Shaft: stainless steel
• Ambient temperature:
-20...+58 °C (IP 56)
-20...+66 °C (IP 54)
• Resistance:
IEC 60068-2-6:2007
Vibration 10 g, 50-2000 Hz
IEC 60068-2-27:2008
Shock 100 g, 6 ms
• Explosion protection:
II 2 G Ex d e IIC T6 Gb
Ex d e IIC T6 Gb
• Connection:
Terminal box
• Weight approx.:
8.8 kg (ø40), 6.2 kg (ш70)