9 technical data, 1 technical data - electrical ratings, 2 technical data - electrical ratings (encoder) – Baumer POG 11 + FSL (version B10 and B10/B3) Benutzerhandbuch

Seite 30: Technical data, Technical data - electrical ratings, Technical data - electrical ratings (encoder)

Advertising
background image

27

Baumer_POG11-FSL-T1_II_DE-EN (14A2)

MB070.1T1 - 11055674

9

Technical data

9

Technical data

9.1

Technical data - electrical ratings

Interference immunity:

EN 61000-6-2:2005

Emitted interference:

EN 61000-6-3:2007/A1:2011

Approvals:

CE, RoHS

9.2

Technical data - electrical ratings (encoder)

Voltage supply:

9...30 VDC* (HTL-P, TTL - version R)

5 VDC ±5 % (TTL)

Consumption w/o load:

≤100 mA

Pulses per revolution:

300...2500 (As precised on order)

Phase shift:

90° ±20°

Duty cycle:

40...60 %

Reference signal:

Zero pulse, width 90°

Output frequency:

≤120 kHz

(≤170 kHz at 500, 512, 1000, 1024, 1200, 2048 and

2500 pulses per revolution)

Output signals:

K1, K2, K0 + inverted

Error output (only EMS)

Output stage:

HTL-P (power linedriver)

TTL/RS422

(As precised on order)

Sensing method:

Optical

9.3

Technical data - electrical ratings (centrifugal switch)

Switching accuracy:

±4 % (Δn = 2 rpm/s)

≤ +20 % (Δn = 1500 rpm/s)

Switching deviation cw-ccw rotation:

≤3 %

Switching hysteresis:

~40 % of switching speed

Switching outputs:

1 output, speed control

Output switching capacity:

≤6 A / 230 VAC

≤1 A / 125 VDC

Minimum switching current:

50 mA

* The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution