9 technical data, 1 technical data - electrical ratings, 2 technical data - electrical ratings (encoder) – Baumer POG 11 + FSL (version B10 and B10/B3) Benutzerhandbuch
Seite 30: Technical data, Technical data - electrical ratings, Technical data - electrical ratings (encoder)

27
Baumer_POG11-FSL-T1_II_DE-EN (14A2)
MB070.1T1 - 11055674
9
Technical data
9
Technical data
9.1
Technical data - electrical ratings
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
• Approvals:
CE, RoHS
9.2
Technical data - electrical ratings (encoder)
• Voltage supply:
9...30 VDC* (HTL-P, TTL - version R)
5 VDC ±5 % (TTL)
• Consumption w/o load:
≤100 mA
• Pulses per revolution:
300...2500 (As precised on order)
• Phase shift:
90° ±20°
• Duty cycle:
40...60 %
• Reference signal:
Zero pulse, width 90°
• Output frequency:
≤120 kHz
(≤170 kHz at 500, 512, 1000, 1024, 1200, 2048 and
2500 pulses per revolution)
• Output signals:
K1, K2, K0 + inverted
Error output (only EMS)
• Output stage:
HTL-P (power linedriver)
TTL/RS422
(As precised on order)
• Sensing method:
Optical
9.3
Technical data - electrical ratings (centrifugal switch)
• Switching accuracy:
±4 % (Δn = 2 rpm/s)
≤ +20 % (Δn = 1500 rpm/s)
• Switching deviation cw-ccw rotation:
≤3 %
• Switching hysteresis:
~40 % of switching speed
• Switching outputs:
1 output, speed control
• Output switching capacity:
≤6 A / 230 VAC
≤1 A / 125 VDC
• Minimum switching current:
50 mA