Technical data

9

9

Technical data

9.1

Technical data - electrical ratings
Voltage supply:

9...30 VDC (HTL)

5 VDC ±5 % (TTL)

9...26 VDC (TTL - R)

Consumption w/o load:

≤100 mA

Pulses per revolution:

1...5000 (As precised on order)

Phase shift:

90° ±20°

Duty cycle:

40...60 %

Reference signal:

Zero pulse, width 90°

Sensing method:

Optical

Output frequency:

≤120 kHz (pulses ≤1250)

≤250 kHz (pulses >1250)

Output signals:

K1, K2, K0 + inverted

Output stage:

HTL

TTL/RS422

(As precised on order)

Interference immunity:

EN 61000-6-2:2005

Emitted interference:

EN 61000-6-3:2007/A1:2011

Approvals:

CE, RoHS

9.2

Technical data - mechanical design
Size (flange):

ø115 mm

Shaft type:

ø11 mm solid shaft

Shaft loading:

≤200 N axial

≤350 N radial

Flange:

EURO flange B10

Protection DIN EN 60529:

IP 56

Operating speed:

≤6000 rpm (T5, mechanical)

≤4500 rpm (T6, mechanical)

Operating torque typ.:

4 Ncm

Rotor moment of inertia:

290 gcm²

Materials:

Housing: aluminium die-cast

Shaft: stainless steel

Ambient temperature:

-20...+55 °C

Resistance:

IEC 60068-2-6:2007

Vibration 10 g, 50-2000 Hz

IEC 60068-2-27:2008

Shock 100 g, 6 ms

Explosion protection:

II 2 G Ex d e IIC T5/T6 Gb

Ex d e IIC T5/T6 Gb

Connection:

Terminal box

Weight approx.:

3.5 kg