10 technical data, 1 technical data - electrical ratings, 2 technical data - mechanical design – Baumer FOG 9 Benutzerhandbuch
Seite 29: Technical data, Technical data - electrical ratings, Technical data - mechanical design

MB195 - 11096124
Baumer_FOG9_II_DE-EN (14A2)
26
Technical data
10
10
Technical data
10.1
Technical data - electrical ratings
• Voltage supply:
9...30 VDC* (HTL-P, TTL - version R)
5 VDC ±5 % (TTL)
• Consumption w/o load:
≤100 mA
• Pulses per revolution:
100...5000 (As ordered)
• Phase shift:
90° ±20°
• Scan ratio:
40...60 %
• Reference signal:
Zero pulse, width 90°
• Sensing method:
Optical
• Output frequency:
≤120 kHz
(≤300 kHz option)
• Output signals:
K1, K2, K0 + inverted
Error output (only EMS)
• Output stages:
HTL-P (power linedriver)
TTL/RS422
(As ordered)
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
• Approvals:
CE, UL approval / E256710
10.2
Technical data - mechanical design
• Size (flange):
ø115 mm
• Shaft type:
ø10...11 mm solid shaft (As ordered)
• Shaft loading:
≤200 N axial; ≤300 N radial
• Flange:
EURO flange B10
• Protection DIN EN 60529:
IP66
• Operating speed:
≤10000 rpm (mechanical)
• Starting torque:
≤6 Ncm
• Rotor moment of inertia:
160 gcm
2
• Materials:
Housing: aluminium die-cast
Shaft: stainless steel
• Operating temperature:
-30**…+100 °C (Version with flange connector)
-30**…+80 °C (Version with connecting cable)
(restricted in potentially explosive environments, see section 2)
• Resistance:
IEC 60068-2-6:2007
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27:2008
Shock 100 g, 6 ms
• Explosion protection:
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
• Connection:
Flange connector M23, 12-pin
Mating connector
• Weight approx.:
700 g
* The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
** Up to -25 °C for versions >3072 pulses per revolution