10 technical data, 1 technical data - electrical ratings, 2 technical data - mechanical design – Baumer POGS 90 Benutzerhandbuch

Seite 27: Technical data, Technical data - electrical ratings, Technical data - mechanical design

Advertising
background image

MB181 - 11067696

Baumer_POGS90_II_DE-EN (13A1)

24

Technical data

10

10

Technical data

10.1

Technical data - electrical ratings

•

Voltage supply:

5 VDC ±10 % (version DN ...)

9...30 VDC (version DN ... R)

•

Consumption w/o load:

≤90 mA

•

Sinewave cycles per turn:

720...5000 (like precised on order)

•

Phase shift:

90°

•

Reference signal:

Zero pulse, width 90°

•

Sensing method:

Optical

•

Output signals:

K1, K2, K0 + inverted

•

Output circuit:

SinCos 1 Vpp

•

Difference of SinCos amplitude:

≤20 mV

•

Harmonics typ.:

-50 dB

•

DC offset:

≤20 mV

•

Bandwidth:

250 kHz (-3 dB)

•

Interference immunity:

EN 61000-6-2:2005

•

Emitted interference:

EN 61000-6-3:2007/A1:2011

•

Approvals:

UL approval / E256710

10.2

Technical data - mechanical design

•

Dimensions (flange):

ø115 mm

•

Shaft type:

ø11 mm solid shaft

•

Shaft loading:

≤250 N axial

≤350 N radial

•

Flange:

EURO flange B10

•

Protection DIN EN 60529:

IP 66

•

Operating speed:

≤10000 rpm (mechanical)

•

Operating torque typ.:

2 Ncm

•

Rotor moment of inertia:

320 gcm²

•

Materials:

Housing: aluminium die-cast alloy and stainless steel

Shaft: stainless steel

•

Operating temperature:

-20...+85 °C

(restricted in potentially explosive environments, see section 2)

•

Resistance:

IEC 60068-2-6

Vibration 10 g, 10-2000 Hz

IEC 60068-2-27

Shock 100 g, 11 ms

•

Explosion protection:

II 3 G Ex nA IIC T4 Gc (gas)

II 3 D Ex tc IIIC T135°C Dc (dust)

•

Connection:

Terminal box

•

Weight approx.:

1.5 kg