9 technical data, 1 technical data - electrical ratings, 2 technical data - mechanical design – Baumer EEx OG 9 S Benutzerhandbuch
Seite 25: Technical data, Technical data - electrical ratings, Technical data - mechanical design
MB051a - 11102670
Baumer_EEXOG9S_II_DE-EN (13A3)
22
Technical data
9
9
Technical data
9.1
Technical data - electrical ratings
• Voltage supply:
5 VDC ±5 % (version DN ...)
9...30 VDC (version DN ... R)
• Consumption w/o load:
≤90 mA
• Sinewave cycles per turn:
1024...2048 (like precised on order)
• Phase
shift:
90°
• Reference signal:
Zero pulse, width 90°
• Sensing
method:
Optical
• Output signals:
K1, K2, K0 + inverted
• Output circuit:
SinCos 1 Vpp
• Difference of SinCos amplitude:
≤20 mV
• Harmonics typ.:
-50 dB
• DC offset:
≤20 mV
• Bandwidth:
250 kHz (-3 dB)
• Interference immunity:
EN 61000-6-2:2005
• Emitted interference:
EN 61000-6-3:2007/A1:2011
9.2
Technical data - mechanical design
• Dimensions (flange):
ø115 mm
• Shaft type:
ø11 mm solid shaft
• Shaft loading:
≤200 N axial
≤350 N radial
• Flange:
EURO flange B10
• Protection:
DIN EN 60529 IP 56
• Operating speed:
≤6000 rpm (T5, mechanical)
≤4500 rpm (T6, mechanical)
• Operating torque typ.:
4 Ncm
• Rotor moment of inertia:
290 gcm²
• Materials:
Housing: aluminium die-cast
Shaft:
stainless
steel
• Ambient temperature:
-20...+55 °C
• Resistance:
IEC
60068-2-6
Vibration 10 g, 50-2000 Hz
IEC
60068-2-27
Shock 100 g, 6 ms
• Explosion protection:
II 2 G Ex d e IIC T5/T6 Gb
Ex d e IIC T5/T6 Gb
• Connection:
Terminal
box
• Weight approx.:
3.5 kg