Gs c0 m n – Citizen Systems CBM1000 Benutzerhandbuch

Seite 161

Advertising
background image

— 143 —

GS C0 m n

[Function]

Setting the numbering print mode.

[Code]

<1D>H<43>H<30>H<m><n>

[Range]

0

m

5

0

n

2

[Outline]

This command sets the numbering(serial number counter) print
mode. m denotes the number of print columns.

m=0

Prints the columns indicated by numeral. In theis
case, n has no meaning.

m=1 to 5

Indicates the maximum number of columns to be
printed.
If a counter value is larger than this the number of
columns set with this command, the printer will
the lower m-columns of the counter value.

n specifies a printing position within the printing columns.
n=0

Prints the data right justified. The blank columns
are spaced.

n=1

Prints the data right justified. The blank columns
are filled with "0".

n=2

Prints the data left justified. The right blank will
become invalid.

[Caution]

• If either m or n has a value beyond their ranges, that setting

will becomes invalid.

[Default]

m = 0 , n = 0

[See Also]

GS C1, GS C2, GS c, GS C;

[Sample Program]

[Print Result]

LPRINT CHR$(&H1D) ;”C0”;
LPRINT CHR$(0);CHR$(0);
GOUSAB *CNT
LPRINT CHR$(&H1D);”C0”;
LPRINT CHR$(1); CHR$(0);
GOUSAB *CNT
LPRINT CHR$(&H1D);”C0”;
LPRINT CHR$(3) CHR$(0);
GOUSAB *CNT
LPRINT CHR$(&H1D);”C0”;
LPRINT CHR$(3); CHR$(1)
GOUSAB *CNT
LPRINT CHR$(&H1D);”C0”;
LPRINT CHR$(3) CHR$(2);
GOUSAB *CNT
END

12345 <

Counts from 1 to 5 at m = 0 and n = 0.

67890 <

Counts from 6 to 10 at m = 1 and n = 0.

11 12 13 14 15 <

Counts from11 to 15 at m = 3 and n = 0.

0160 170 180 19020 < Counts from 16 to 20 at m = 3 and n = 1.
21 22 23 24 25 <

Counts from 21 to 25 at m = 3 and n = 2.

*CNT
FORI = 1 TO 5
LPRINT CHR$(&H1D);”c”;
NEXT I
LPRINT CHR$(&HA);
RETURN