GS C2 n1 n2

[Function]

Setting the numbering counter

[Code]

<1D>H<43>H<32>H<n1><n2>

[Range]

0

n1

255

0

n2

255

[Outline]

This command sets the numbering (serial number counter)
value.

n1 + n2 x 256(n1= remainder, n2=quotient) becomes a counter
value.

[Caution]

• If the counter is set with this command, a repeat count of the

idential count will be cleared. If the counter value is beyond
the Range specified with the "GS C1" or "GS C;" command,
the counter will be initialized.

[Default]

Not defined.

[See Also]

GS C0, GS C1, GS c, GS C;

[Sample Program]

[Print Result]

See the sample program and print result for the GS C1

command.