6. Scope of Delivery, Accessories and Spare Parts
6.1 Scope of Delivery
The Compur Ex plus (with standard or longterm battery) will be delivered with the following
parts:
??Gasdetector with sensor, calibrated on desired gas
??Battery pack, standard or longterm, charged
??Keyboard pin
??Operating instructions
6.2 Accessories, Spare Parts
see enclosure
7. Technical Data
Measuring components
combustible gases and vapours
Measuring range
0 to 100 % LEL
Principle of measurement
catalytic combustion
Response time
t
90
< 10 s, at 20 °C (68°F)
Alarm levels
2, adjustable over full range
Alarm
audible: typ.: > 80 dB(A) (30 cm)
optical: LED
Dimensions:
115 x 64 x 24 mm
(with standard battery pack)
(4,5 x 2,5 x 0,9 in.) h x w x l
Weight with standard battery pack
225 g (7,5 uz)
Weight with longterm battery pack
375 g (13,3 uz)
Power supply
longterm: NiCd battery pack
standard: NiMH battery pack
Power consumption
max. 140 mA
Operation time
standard battery: 4 h
longterm battery: 15 h
Operational tmeperature range
- 20°C to 40 °C
Relative humidity range
5 % r. h. to 99 % r. h.
Pressure range
90 – 110 kPa
Storage temperature
- 30°C to 70°C
Outputs
earphone jack
Protection class
IP 54
Ex-certificate
Sensor: Ex s IIC
instrument: EEx ib IIC T4