Specification td-23 ac – Westermo TR-23 Benutzerhandbuch
Seite 9

9
6600-2002
Specification TD-23 AC
Transmission:
Asynchronous, full/half duplex or simplex
Interface 1
EIA RS-232-C/CCITT V.24/V.28, 9-pin D-sub female or
9-pin detachable screw block (only signals SG, RD, TD,
are available)
Interface 2
EIA RS-422/RS-485/CCITT V.11 detachable
9-pin screw block
Interface 3
CCITT V.23. 2- or 4-wire. 4 pin detachable screw block
Transmission rate
Up to 1200 bit/s
LED Indicators
PWR, RD, TD, RTS, CTS, DCD
Isolation
Transformer (power supply and line interface) 3000V
Overvoltage protection
Mains: breakdown voltage 440V at 230V AC
and 220V at 115V AC
Line: Zener diodes, breakdown voltage 68V,
discharge 600W for 1 ms, gas tubes 300V
Power supply
230V AC +15% –10%, option 115V AC
Fuse
100 mA, fast
Power consumption
<2W
Temperature range
5–50 Deg C ambient temperature
Humidity
0–95% RH, non-condensing
Dimension
55x100x128 mm
Weight
0.4 kg
Mounting
35 mm DIN-rail