VHM Camera Housing
Screw Terminal, Heater, Thermostat Switch
1. Safety instructions
The following instructions are for your
own care and should be observed
without any fail.
• Please read safety notes and following
installation instructions before putting
the individual components into
operation.
• Keep the installation instructions
carefully stored for later reference.
• Screw terminals are only intended for
permanent connection to the power
supply network.
• Connector sleeves are to be used if
flexible connecting leads are being
used.
• The safety earth terminal must be
wired leading and attention paid to the
correct allocation of L1 and N.
• Attention must be paid to safety when
laying mains cable and lay the cable
so that it is not subjected to any loads,
kinks, damage or damp.
• An easily accessible all-pole circuit
breaker with a minimum normal gap
construction of 3 mm is to be installed
close to the unit in order to be able to
isolate the unit for maintenance work.
The safety earth connection must have
low impedance in conformity with the
electrical safety regulations.
• Connection work must be carried out
by a qualified electrician.