Trouble shooting, Gb ie cy – Florabest FHE 710 A1 Benutzerhandbuch

Seite 21

Advertising
background image

21

GB IE

CY

Trouble shooting

Problem

Possible cause

Fault correction

Device does not

start

Mains voltage defective

House protection fuse activated

Check plug socket, cable, line and

plug, where appropriate, repair by

electrical specialist.

Check house protection fuse, see note

Defective On/Off switch (

10)

Repair by customer service

Worn carbon brushes

Repair by customer service

Defective motor

Repair by customer service

Inferior cutting

performance

Incorrectly mounted saw chain

(

1)

Mount saw chain correctly

Saw chain (

1) blunt

Sharpen cutting teeth or place on

new chain

Chain tension insufficient

Check chain tension

Saw runs with

difficulty, chain

(1

) comes

off

Chain tension insufficient

Check chain tension

Chain (

1) becomes

hot, smoke

development

during sawing,

discoloration of

the rail

Too little chain oil

Check oil level and, where appro-

priate, refill with chain oil,

check oil automatic system and,

where appropriate, clean oil outlet

channel (

22 or have repaired

by customer service

Check fine-tuning for lubrication

system (oil regulation button).

Telescopic han-

dle cannot be

locked

Allen screw (

17b) loose on

the quick release (

17)

Tighten Allen screw