Jøtul f 500 woodstove clearances, Usa/canada – Jotul F 500 Benutzerhandbuch

Seite 16

Advertising
background image

16

USA/CANADA

Stove clearances

Unprotected surface

Protected surface NFPA 211

Parallel installation

Parallel installation

Side

Rear

Corner*

Side

Rear

Corner*

Stove- no heatshields

14" A

18" B

13" C

6" D

12" E

9" F

Single wall pipe

355mm

460mm

330mm

150mm

300mm

230mm

Stove with rear heatshield

14" G

10" H

9" I

6" J

10" K

9" L

Single wall pipe

355mm

255mm

230mm

150mm

255mm

230mm

Stove with rear heatshield

14" M

6" N

9" O

6" P

6" Q

6" R

With connector shield

355mm

150mm

230mm

150mm

150mm

150mm

Stove with rear heatshield

14" S

6" T

9" U

6" V

6" W

6" X

With double wall pipe

355mm

150-mm

230mm

150mm

150mm

150mm

Connector

Unprotected surface

Protected surface NFPA 211

clearances (pipe)

Vertical installation

Vertical installation

Single wall pipe

18"

12"

460mm

300mm

Single wall pipe

6"

6"

with connector shields

150mm

150mm

Double wall pipe

6"

6"

150mm

150mm

Connector

Unprotected surface

Protected surface NFPA 211

clearances (pipe)

Horizontal installation

Horizontal installation

Single wall connector

18" 460mm

12" 300mm

Double wall pipe

6" 150mm

6" 150mm

Mantel and trim

Stove to 1" thick or less, side trim

12" 300mm

clearances

Stove to 1" thick or less, top trim

16" 410mm

Stove to mantel- maximum mantel depth 12"

30" 765mm

* Attention: Stove and pipe clearances must both be taken into
Consideration. The greater clearance dictates the stove’s position.

* Use of the right side load door is prohibited in alcove and
Corner installations.

Jøtul F 500 Woodstove Clearances