Barracuda 4 Installation Guide, Rev. E

17

1

1

Measured with average reading DC ammeter. Instanta-

neous +12V current peaks will exceed these values.

1

2

A –10% tolerance is permissible during initial start of

spindle and must return to ±5% before 7,200 RPM is
reached. The ±5% must be maintained after the drive
signifies that its power-up sequence has been completed
and that the drive is able to accept selection by the host
initiator.

1

3

See the +12V current profile in the

Barracuda 4 Product

Manual

(publication number 83328880).

1

4

This condition occurs when the Motor Start Option is

enabled and the drive has not yet received a Start Motor
command.

1

5

See “Conducted noise immunity” in the

Barracuda 4

Product Manual.

Specified voltage tolerance is inclusive

of ripple, noise, and transient response.

1

6

At power-up, the motor current regulator limits the 12V

current to an average value of less than 2.18A, although
instantaneous peaks may exceed this value. These peaks
should measure 5 msec duration or less.

1

7

Minimum current loading for each supply voltage is not

less than 3% of the maximum operating current shown.

1

8

The +5V and +12V supplies employ separate ground

returns.

No terminator power. See Section 11.7.3.4 in the

Barra-

cuda 4 Product Manual.

continued