Caution:

Keep the DC Power ON/OFF switch of the

camera control unit in the OFF position through the
installation.

Camera Head with GP-LM7TA, GP-
LM15TA, GP-LM24TA or GP-LP12TA

1. Remove the body cap of the camera and confirm

that the surface of the optical filter of the camera
head is clean.

If the surface of the optical filter is not clean, use a
blower brush or lens cleaning tissue.

2. Rotate the focus lock ring fully clockwise.

Mount the Pinhole Lens, Wide-angle Lens or Tele-
angle Lens to the camera by rotating it clockwise
slowly.

Body Cap

Focus Lock Ring

PREPARATION

Camera Head with GP-AD22TA and
optional C-mount lens

1. Remove the body cap of the camera head and con-

firm that the surface of the optical filter of the cam-
era head is clean.

If the surface of the optical filter is not clean, use a
blower brush or lens cleaning tissue.

2. Attach the optional C-mount lens to the C-mount

adapter GP-AD22TA by rotating it clockwise.

3. Rotate the focus lock ring fully.

Mount the lens and C-mount adapter by rotating
them clockwise slowly.

Caution:

If the optional C-mount lens size exceeds

50mm (2”) in diameter, 70mm (2-3/4”) in length
and 300

g (0.66 lbs) in weight, both the camera

and lens should be secure.

Body Cap

Focus Lock Ring