Building-in – Zanussi ZOU 461 Benutzerhandbuch

Seite 38

Advertising
background image

38

Fig. 10

Building-in

To ensure correct operation of the built-in assembly, the
kitchen cabinet and the recess for the built-in appliance must
have suitable dimensions. When the appliance is fitted-in,
there must be no open spaces left and it must be closed on
all sides by the kitchen furniture to prevent the possibility of
inadvertently touching “live” (current carrying) parts of the
oven. All parts ensuring such a protection, including any
covering panel (for instance, if the appliance is installed at the
end or at the beginning of a kitchen counter) must be fastened
in such a way as to prevent removal of the same without the
aid of some tool. This appliance can be placed with its back
and with one side close to appliances or walls of higher
height. The other side, instead, must be placed close to
furniture or appliances, having the same height.

Overall oven dimensions (Fig. 10)

230V 3~

1 2 3 4 5

L1 L2 L3 PE

230V 1~

1 2 3 4 5

L1 N PE

400V 2N~

1 2 3 4 5

L1 L2 N PE

400V 3N~

1 2 3 4 5

L1 L2 L3 N PE

Ø 4x2,5mm²

Ø 3x2,5mm²

Ø 4x2,5mm²

Ø 5x1,5mm²

Fig. 8

Fig. 9

Connecting the terminal board

The appliance incorporates an easily accessible 6-pole terminal

board whose jumpers (bridges) are already pre-set for operation

on 400 V tri-phase with neutral wire (Fig. 8). In case a different

mains voltage is present, the jumpers on the terminal board must

be rearranged as shown in the diagram (Fig. 9). The ground
cable must be connected to terminal

. After connecting the

supply cable to the terminal board, secure it with a junction

clamp.

Electrical connection with the hob

This oven can be connected to hobs indicated in the

paragraph "Technical data". The socket for connecting the

hob is located at the top of the oven cabinet. The hobs

come complete with connecting leads for the hot plates/

heat areas and ground cable; these leads feature plug-in

connectors. Connection of the hob to the oven is carried

out by plugging-in these connectors to the corresponding

oven socket.

The plug-to-socket connection design is such as to prevent

possible wrong plugging-ins.
The Manufacturer disclaims any liability in case

these accident-preventing rules are not observed.

Advertising