5.6 Saving the parameter adjustment

data

It is recommended noting the adjusted data, e.g. in

this operating instructions manual and archive

them afterwards. They are hence available for

multiple use or service purposes.
If VEGASON S 61 is equipped with an indicating

and adjustment module, the most important data

can be read out of the sensor into indicating and

adjustment module. The procedure is described in

the operating instructions manual "Indicating and

adjustment module" in the menu item "Copy sensor

data". The data remain there permanently even if

the sensor power supply fails.
If it is necessary to exchange VEGASON S 61, the

indicating and adjustment module is inserted into

the replacement instrument and the data are

written into the sensor under the menu item "Copy

sensor data".

6 Setup with PACTware™ and

other adjustment programs

6.1 Connecting the PC

Connecting the PC directly to the sensor

2

1

Fig. 28: Connection directly to the sensor

1

USB cable

2

VEGASON S 61

3

Voltage supply

Necessary components:

l

VEGASON S 61

l

PC with PACTware™ and suitable VEGA DTM

l

VEGACONNECT 4

l

Power supply unit

6.2 Parameter adjustment with

PACTware™

Further setup steps are described in the operating

instructions manual "DTM Collection/PACTware™"

attached to each CD and which can also be

downloaded from our homepage. A detailed

description is available in the online help of

PACTware™ and the VEGA DTMs.

Note:

Keep in mind that for setup of VEGASON S

61, DTM-Collection 06/2003 or a newer

version must be used.
All currently available VEGA DTMs are

provided in the DTM Collection on CD and

can be obtained from the responsible

VEGA agency for a token fee. This CD

includes also the up-to-date PACTware™

version. The basic version of this DTM

Collection incl. PACTware™ is also avail-

able as a free-of-charge download from the

Internet.Go via www.vega.com and "Down-

loads" to the item "Software".

7 Maintenance and fault

rectification

7.1 Maintenance

When used as directed in normal operation,

VEGASON S 61 is completely maintenance free.

7.2 Remove interferences

Causes of malfunction

VEGASON S 61 offers maximum reliability.

Nevertheless, faults can occur during operation.

These may be caused by the following, e.g.:

l

Sensor

l

Process

l

Supply

l

Signal processing

VEGASON S 61

35

Setup with PACTware™ and other adjustment programs