Festo Линейные модули HMP Benutzerhandbuch

Seite 20

Advertising
background image

HMP−...−B−...−Z..−...

Festo HMP−...−B−...−Z..−... 0412NH English

20

Please note
S Take into account the minimum distances L in accordance with the following

table:
ć end position and intermediate position module
ć shock absorber and intermediate position module
ć several intermediate position modules (only on demand).

Position

Front end
position (L1)

Between the
modules (L5)

Rear end position
(L3)

Extending

Retracting

Fig. 4

HMP−ø−B−Z1..−...

16

20

25

32

L1 (extending) [mm]

66

68.5

54.5

56

L3 (extending) [mm]

33

42

42

55.5

L1 (retracting) [mm]

33

42

42

55.5

L3 (retracting) [mm]

47.5

62

54.5

56

L5 (between the modules)
[mm]

102

102

102

135

Fig. 5

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: