9

Eliminating faults

Fault

Possible cause

Remedy

Hard striking of
the stop lever

Transport time too brief
(speed too high)

Increase transport time (reduce
speed)

Mass too large

Reduce the mass

Rubber buffer worn

Replace rubber buffer

Linear module moves
against a non−pressurized
chamber

Pressurize the cylinder chamber
on the stroke side of the linear
module

Stop lever does
not move out

Pressure at intermediate
position module too low

Pressurize the intermediate posiĆ
tion module with at least 4 bar

Incorrect actuation

Check the pneumatic circuit
diagram

Intermediate position
module defective

Return to Festo

Faults in position
scanning

Multiple switching cycles

Consider the direction of moveĆ
ment for setting the proximity
switch (see chapter Fitting elecĆ
tric components")

Incorrect type of proximity
switch used

Use only proximity switches of
type SME/SMT−10−...

Proximity switch defective

Replace proximity switch

Position of proximity
switches incorrect

Correct position of proximity
switches

Fig. 20