Fitting electric components – Festo Линейные модули HMP Benutzerhandbuch

Seite 23

Advertising
background image

HMP−...−B−...−Z..−...

Festo HMP−...−B−...−Z..−... 0412NH English

23

Fitting electric components

For position scanning:

S

Push the required number of proximity switches into the appropriate grooves
in acccordance with the table below.

With the intermediate position module there may, under certain circumĆ
stances, be multiple switching cycles as a result of unfavourable tolerance
conditions. The setting direction of the proximity switches must therefore be
observed as shown in the following diagrams.

Scanning

Position of the
retracted stop
lever

Position of the
extended stop
lever

Position of the guide
tube (end position and
intermediate position)

HMP−...−B−...−
Z1A−...

HMP−...−B−...−
Z1E−...

Position

On the intermediate position module

2

(note plug−in direction)

On the sensor strip

9

Type (proximity
switches)

SME−10..−.../
SMT−10..−...

SME−8..−.../
SMT−8..−...

Fig. 12

The recesses (B) and (C) in the end cover of
the linear module enable proximity switch
cables to be passed outside where they can
then be connected to the terminal strip of the
electric interface, module HMP−...−EL.

Fig. 13

(B)

(C)

Advertising