5. Accelerate the work load in steps until the operating speed is reached.

Pease refer to the calculations for your application for the speed required.
Linear module type HMP−...−B−... must not strike hard against the intermediate
position.

Concluding the test run:

6. Make sure that the guide tube of the linear module is in the park position.

7. Exhaust linear module type HMP−...−B−... and the intermediate position module

HMP−...−B−...−Z..−...Ă.

6

Care and maintenance

S

If the intermediate position module is dirty, clean it with a soft cloth.

Permitted cleaning agents are:

ć soap suds (max. 60 °C)
ć all non−abrasive media.

S

Replace the buffer elements on the
housing (D) or on the stop lever (E) in
order to minimize noise:

ć if the stop lever can be heard to strike

hard

ć at the latest every 3 million switching

cycles.

Otherwise the intermediate position module
does not require any maintenance.