Festo Пропорциональные распределители MPYE Benutzerhandbuch

Seite 23

Advertising
background image

Setpoints:
- Setpoint voltage
- Setpoint current

DC 0 ... + 10 V

mid-position at 5 V

(voltage variant, types MPYE-5-...-010B)

4...20 mA

mid-position at 12 mA

(current variant, types MPYE-5-...-420B)

Input current
(setpoint)

80

μA at 10 V (voltage variants Types MPYE-5-...-010B

0

μA at 5 V

- 80

μA at 0 V

Input resistance
(setpoint)

300

Ω (with current variant, types MPYE-5-...-420B)

Power consumption:
- Piston mid-position
- Maximum

2 W
max. 20 W

Degree of protection

IP 65 with correctly-fitted connector socket as described in "Accessories"

EMC
(housing earthed with
earthing screw and
cable screening earthed at
opposite end from valve)

- Immunity to interference as per EN 61000-6-2 (industry)

*)

The following minimum operating quality is guaranted when there is interference from electromagnetic
HF-Fields as per EN 61000-4-3: The piston slide remains within the nominal cover range.

- Interference emission as per DIN EN 61000-6-4 (industry)

*)

Standard nominal flow rate

100 l/min (

±10 %)

350 l/min (

±10 %)

700 l/min (

±10 %)

1400 l/min (

±10 %)

2000 l/min (

±10 %)

Max. leakage rate in new
condition (6 bar, outlets 2
and 4 closed)

7 l/min

20 l/min

25 l/min

30 l/min

35 l/min

Hysteresis

Max. 0.4% relative to maximum slide stroke

Materials

Housing:

Anodised aluminium

Electronics housing: Galvanised ABS

Seals:

NBR

Valve slide and sleeve:Hardened aluminium

Screws: Galvanised

steel

Weight

0.290 kg

0.330 kg

0.330 kg

0.530 kg

0.740 kg

Fig. 24

*) The MPYE-... is intended for industrial use only.

1304f