Technical specifications – Festo Вакуумные генераторы VADMI Benutzerhandbuch

Seite 29

Advertising
background image

Technical specifications

General specifications:

Design

Vacuum generator with controlled Laval nozzle

Fitting position

As desired

Medium

Filtered, non-lubricated compressed air (filter fineness min. 40

μ

m)

Operating pressure

1.5 ... 8 bar (with VADMI-45-... to VADM(I)-70-...)
2 ... 8 bar (with VADM(I)-95-... to VADM(I)-300-...)

Permitted temperature range

0 ... + 50 °C

Power consumption of the solenoids

1,5 W

Supply voltage for


solenoid valve: + 24 V DC

±

10%; + 24 V DC +10%/-5%(with VADMI-70-LS-P/N)

vacuum switch: + 15 ... 30 V DC (rated value 24 V DC)

Temperature influence on switching point and hysteresis

max. 10 mbar/10 K

Voltage drop at switching output

max. 1.8 VDC

Switching output current

130 mA

Internal current consumption

25 mA (with VADMI-...-LS

25 mA)

Setting range:

vacuum switching point
hysteresis

0 ... max. -0.9 bar

- 0.2 ... max. -0.9 bar (only with VADMI-...-LS-P/N)

0.05 ... max. 0.5 bar

0.1 ... max. 0.6 bar (only with VADMI-...-LS-P/N)

Electrical connection

Protected against incorrect polarity

EMC

Immunity to interference as per DIN EN 61000-6-2 (industry)
Interference emission as per DIN EN 61000-6-4 (industry)

Max. permitted signal cable length

30 m

Protection class

IP65 in conjunction with connection sockets as per accessories

Materials

Housing: Al
Internal parts:

brass

Silencer cover:

POM

Silencer insert:

polyethylene, sintered

Slotted head screws: St
Filter: polyethylene

fabric/PA

66

Filter cover:

PC

Slide: PA

6

Seals: NBR
Lubrication: silicon

free

Vacuum switch
housing: PET/

PA

Fig. 42

13

0503i

D/GB 29

Advertising