faytech 15'' IP65 Touch Monitor Benutzerhandbuch

Seite 51

Advertising
background image

51

You can adjust the parameter for the Constant Touch Area function. This is a criterion to judge

if the most recent touched point is the same as the previously touched point. If the difference

between the two points is within this area, it will be recognized as the same touch point and the

driver does not generate a new mouse event for this touch point.

You can adjust the Auto Right Click Time function. If the touch screen is touched and held for

this period of time, the driver generates a right mouse click.

3. Tools tab:

You can adjust the faytech touch panel calibration with the functions called 4 Points

Calibration, Clear and Calibrate, Linearization and Draw Test. Start by performing the 4

points calibration. By using the application drawing test, you can test the touch panel to

determine if further setting changes are desirable.

When you press the 4 Points Calibration button, the surface of the monitor shows the following

image:

Press blinking X symbol until stop blinking Touch and hold each of the blinking X symbols in

the calibration window until it stops blinking to make sure that the utility can gather enough

data for computation. In addition, a progress bar is shown at the bottom of the window to

indicate time elapsed. If the touch screen is not touched before the progress bar gets to the far

right, the calibration task will be terminated automatically.