Tangent, Position 1 position 2 – Clearaudio Tangent (Tangential) Benutzerhandbuch

Seite 21

Advertising
background image

Tangent


Bedienungsanleitung / User manual

Page / Seite 21

clearaudio electronic GmbH 2015

The following step will ensure real linear tracking. You will need the delivered linear
gauge for this adjustment. Slide the gauge over the spindle of the platter and turn it
under the chassis of the tonearm. Please remove the LP if used one before ! Lift the
cartridge down and position the diamond on the black line of the gauge. Do this step at
the beginning (Position 2) and also at the end (Position 1) of the LP (imagine that there
is now one on your platter). This adjustment is successful, if the diamond is in all
positions on the black line. To change the position of the diamond, please unlock the
screw on the top of the carriage with the hex key wrench and move the headshell
forward or backward until the diamond sits exact on the black line. This adjustment is
very
important to ensure the real linear tracking ability of your tangent.












Position 1

Position 2