3.2 Set to factory default

3.4 Standalone mode

3.3 DMX Addressing

Enter DMX address by means of the keys + and -. Confirm an store by pressing key
ENTER.

To set back the VS 7 to factory setting press key MENU one time.
will be displayed. Press key ENTER to enter fACTIRY DEFAULT menu. Select

and press key ENTER.

will be displayed. Confirm by pressing key

ENTER again. The personal setting of the VS 7 will be set back to factory default.

FACTORY DEFAULT

LOAD

DEFAULTS

SURE

A sequence consisting of preprogrammed cues can be recalled by means of the
Standalone mode. The sequence will run as a loop. Cues can be entered in two different
ways. The first way is to program every feature by means of the key of the units own
control panel. The second way is to program the cues by means of a connected DMX
control console and to store them on-board of the VS 7.

Enter DMX values by means of the control panels keys:

Recall standalone mode: :
Press key MENU first. The press key + five times (see page 24)
will be displayed. Confirm by pressing key ENTER

will be shown. Confirm

again by pressing ENTER After this second confirmation the display will show:

Now recall Modify menu by pressing key ENTER. The Modify menu enables

access to all parameters of the unit. Use key + and - to recall the desired parameter.
Confirm choice by pressing ENTER. Enter DMX values by means of the keys + and -.
Store DMX values by pressing key ENTER. To escape press key MENU.

STANDALONE STEPS

, STEP NR. 1/1,

.

MODIFY 1/1.

Add one step to the sequence:
Press key + untill MENU

is shown. Confirm by pressing key ENTER.

will

be displayed. Confirm by pressing key ENTER again. An new step will be added to the
sequence. The DMX values of the last step will be automatically copied to the new step.
To alter DMX values enter Modify menu and proceed like describe in chapter before. Enter
DMX values by means of the control panels keys

INSERT

SURE?

Delete one step of a sequence:
Recall the Standalone menu.

must be shown on the display.

Confirm by pressing key ENTER.

will be displayed.

Use keys + and - to recall the desired step. Confirm selection by pressing key ENTER.
Select menu DELETE by pressing key +. Confirm the selection of the step by pressing
key ENTER.

will be displayed. Now confirm again by pressing key ENTER and

the selected step will be deleted.

STANDALONE STEPS

STEP NR: 1 / X

SURE?