4 legend cs to cs, Appendix: 12.4 wiring diagrams – Dimplex SI 9CS Benutzerhandbuch

Seite 32

Advertising
background image

32

12.4.4 Legend .. 5CS to .. 17CS

APPENDIX: 12.4 WIRING DIAGRAMS

A1

Wire jumper, must be removed if a utility company disable contactor is used

A2

Wire jumper, must be removed if 2nd disable input is used

A3

Wire jumper, must be removed if a motor protection contact for primary pump is used

A4

Wire jumper, must be removed if a motor protection contact for the compressor is used
Open wire jumpers or contacts mean: lock-out or malfunction

B2*

Pressostat low pressure, brine

B3*

Thermostat, hot water

B4*

Thermostat, swimming pool water

E9*

Electr. immersion heater, hot water

E10*

Suppl. heating system (boiler or electr. heating element)

F2

Load fuse for N1 relay outputs across J12 and J13

4.0 A slow

F3

Load fuse for N1 relay outputs across J15 to J18

4.0 A slow

F4

Pressostat high pressure

F5

Pressostat low pressure (in SI 17CS, F5 is a limiter with manual reset)

F15*

Motor protection M11, from SI 9CS to SI 17CS integrated in primary pump

H5*

Lamp, remote fault indicator

J1...J18

Terminal connector at N1

K1

Contactor, compressor

K5

Contactor, primary pump

K11*

Electron. relay for remote fault indicator (relay module)

K12*

Electron. relay for swimming pool water circulating pump

K20*

Contactor, suppl. heating system

K21*

Contactor, electr. immersion heater, hot water

K22*

Utility company disable contactor

K23*

SPR auxiliary contactor

M 1

Compressor

M11*

Primary pump

M13*

Heating circulating pump

M15*

Heating circulating pump for heating circuit 2

M16*

Suppl. circulating pump

M18*

Hot water circulating pump

M19*

Swimming pool circulating pump

M21*

Mixer heating circuit 1

M22*

Mixer heating circuit 2

N1

Heat pump controller

N7

Soft start control (not fitted in SI 5CS and SI 7CS appliances)

N10*

Remote control station

N11*

Relay module

R1

External sensor

R2

Return sensor

R3

Hot water sensor (as an alternative to hot water thermostat)

R5

Sensor for heating circuit 2

R6

Freeze protection sensor

R7

Coding resistor 8k

T 1

Safety isolating transformer 230/24V AC-28V A

X1

Terminal strip mains control L/N/PE-230V AC-50 Hz/fuses/N and PE-terminal block

X2

Terminal strip 24V AC-terminal block

X3

Terminal strip GND terminal block for sensors R1/-2 and -3 at J2

X4

Terminal stripGND terminal blocl for sensors R5 and -6 at J6

X5

Terminal strip power supply 3 L/PE-400V AC-50 Hz

Abbreviations:

EVS

Utility company disable input

SPR

Supplementary disable input

MA*

Mixer OPEN

MZ

Mixer CLOSED

*Components to be supplied by the customer