Caution - Heating Technicians !

Depending on the filling water quality and

quantity, in particular in the case of mixed

installations and plastic pipes, mineral deposits

(rust sludge, lime) may form, impairing the pro-

per functioning of the heating installation. A

reason for this is the water hardness and

oxygen dissolved in the filling waters as well

as additional oxygen from the air, which may

penetrate via valves, fittings and plastic pipes

(oxygen diffusion). As a preventive measure it

is recommended that a physical water conditio-

ner such as ELYSATOR be used.

9.3 Cleaning of Heat Source Side

The filter screen of the strainer should be cleaned

one day after commissioning, thereafter every week.

If no more contamination can be noticed any more,

the strainer filter can be removed in order to reduce

pressure losses.

9

CARE/CLEANING

CARE/CLEANING

9.1 Care

The heat pump is maintenance-free. To prevent

malfunctions due to sediments in the heat ex-

changers, care must be taken that no impurities can

enter the heat source system and heating installa-

tion. In the event that operating malfunctions due to

contamination occur nevertheless, the system

should be cleaned as described below.

9.2 Cleaning of Heating Side

The ingress of oxygen into the heating water circuit

may result in the formation of oxidation products

(rust). It is therefore important - in particular with

respect to the piping of underfloor heating systems

- that the installation is executed in a diffusion-proof

manner.

Also residues of lubricating and sealing agents may

contaminate the heating water.

In the case of severe contaminations leading to a

reduction of the performance of the condenser in

the heat pump, the system must be cleaned by a

heating technician.

According to current knowledge, we recommend

cleaning with a 5% phosphoric acid solution or, in

the case that cleaning needs to be performed more

frequently, with a 5% formic acid solution.

In either case, the cleaning fluid should be at room

temperature. It is recommended that the heat

exchanger be cleaned in the direction opposite to

the normal flow direction.

To prevent acidic cleaning agents from entering the

circuit of the heating installation we recommend that

the flushing device be fitted directly to the supply

and return lines of the condenser. To prevent any

damage caused by cleaning agent residues that

may be present in the system it is important that the

system be thoroughly flushed using appropriate

neutralising agents.

The acids must be used with great care, all relevant

regulations of the employers' liability insurance

associations must be adhered to.

If in doubt, contact the manufacturer of the chemicals!

CAUTION!

CAUTION!

The supplied strainer is to be install-

ed in the heat source inlet of the heat pump in

order to protect the evaporator against conta-

mination.