5

5

4

ACCESSORIES

4.1 Brine Manifold

The brine manifold ties the individual collector loops

of the heat source system into a single main line

which is connected to the heat pump. Integrated ball

valves allow individual brine circuits to be shut off for

venting purposes.

ACCESSORIES

TRANSPORT

TRANSPORT

A lift truck is suited for transporting the unit on a level

surface. If the heat pump needs to be transported

on an uneven surface or carried up or down stairs,

carrying straps may be used for this type of transport.

These straps may be passed directly underneath

the wooden pallet.

The heat pump is not secured to the

wooden pallet.

The heat pump must not be tilted

more than max. 45

°

(in either direction).

For lifting the unit without pallet, the holes provided

in the sides of the frame should be used. The side

panel assemblies must be removed for this

purpose. A commercially available pipe can be used

as a carrying aid.

Do not use the holes in the panel

assemblies for lifting the unit!

CAUTION!

CAUTION!

CAUTION!