Gb ie cy – Parkside PHD 100 D2 Benutzerhandbuch

Seite 8

Advertising
background image

8

GB

IE

CY

Unsuitable extension cables can

be dangerous as people can be

harmed by an electric shock!

• Protect the electric plug connections

against moisture.

• If there is a risk of flooding, fix the

plug connections in an area that is safe

from flooding.

• Ensure that the mains voltage matches

the specifications on the rating plate.

• The electrical installation shall be ac-

cording to national wiring rules.

• Connection to the mains must be car-

ried out by an experienced electrician

and meet the requirements of IEC

60364-1.

• The device must only be connected to

a mains socket via a residual-current

circuit breaker (RCD) with a rated leak-

age current of not more than 30 mA.

Fuse: at least 13 ampere.

• Before each use, check the equipment,

cable and plug for damage.

• If the power cable for this equipment is

damaged, it must be replaced by the

manufacturer, a customer service agent

of the same or a similarly qualified per-

son in order to prevent hazards.

• Do not pull the plug from the socket by

the cable. Protect the cable from heat,

oil and sharp edges.

• Do not carry or fix the equipment by

the cable.

• Use only extension cables that are pro-

tected from spray water and designed

for outdoor use. Always fully unroll a

cable drum before use. Check the ca-

ble for damage.

• Before any work on the equipment,

during work breaks and in the case

of non-use, remove the plug from the

socket.

• Protect the pressure washer from frost

and dry running.

• Use only original accessories and do

not carry out conversion work on the

equipment.

• Please read the notes in the operating

instructions on the topic of “mainte-

nance and cleaning”. Any measures

above and beyond these, particularly

opening the equipment, are to be car-

ried out by an electrician. In the case

of repairs, always contact our service

centre.

• The washer was designed for opera-

tion with a neutral detergent based on

a biologically decomposable anionic

tenside. Other detergents or chemical

substances could impair the safety of

the washer and damage it.

• If you come into contact with cleaning

agents, rinse with plenty of clean wa-

ter.

• Water that has passed through a back-

flow preventer is classified as undrink-

able.

• High-pressure hoses, fittings and

couplings are important for machine

safety. Use only high-pressure hoses,

fittings and couplings recommended by

the manufacturer.

• To ensure machine safety, use only

original replacement parts from the

manufacturer or replacement parts au-

thorised by the manufacturer.

Electrical safety:

Caution: to avoid accidents and

injuries from electric shocks:

• The plug and socket of an extension

cable must be water-tight!

Advertising