2 Description

2.2 Displays, Operating Elements and Connections

1

LED Row 1-10 V OUTPUT

Displays the measured and amplified signal from the sensor during a measuring. The
best adjustment of the amplification is during a measuring (dispensing) the signal will be
not higher than 5 V. It has to be adjusted at the potentiometer 3.
At the beginning of a measuring cycle the signal increases more than the adjusted 5 V.
It shows you that the pressure sensor works well. If the sensor is damaged, no signal will
be displayed.

2

4 pin Plug

for connection to controller

The supplied connection cord is connected here (Pin assignments see Section 8.2).

3

Potentiometer R10

to adjust the amplification factor

It is necessary to adjust the amplification factor for getting an optimum signal for the
interpretation at the Loctite controller.

4

Service Socket,

for Loctite service only

5

4 pin Socket

for connection the pressure sensor

The cable of the pressure sensor is connected here (Pin assignments see Section 8.2).

1

2

3

4

5