Extended Configuration Menu

Web-Based Management Interface

Intelligent Blade Panel Module

117

6.2.4.3 Managing Access Control (802.1x)

6.2.4.3.1 Defining Access Control Page

Configurable Data

Administrative Mode

- This selector lists the two options for administrative mode: enable

and disable. The default value is disabled.

Command Buttons

Submit

- Sends the updated screen to the IBP and causes the changes to take effect on

the IBP but these changes will not be retained across a power cycle unless a save is
performed.

6.2.4.3.2 Configuring each Port Access Control Configuration Page

Selection Criteria

Port

- Selects the port to be configured. When the selection is changed, a screen refresh

will occur causing all fields to be updated for the newly selected port. All physical
interfaces are valid.

Configurable Data

Control Mode

- This selector lists the options for control mode. The control mode is only

set if the link status of the port is link up. The options are:

force unauthorized:

The authenticator port access entity (PAE) unconditionally sets the

controlled port to unauthorized

force authorized:

The authenticator PAE unconditionally sets the controlled port to

authorized.

auto:

The authenticator PAE sets the controlled port mode to reflect the outcome of the

authentication exchanges between the supplicant, authenticator, and the authentication
server.

Quiet Period

- This input field allows the user to configure the quiet period for the selected

port. This command sets the value, in seconds, of the timer used by the authenticator state
machine on this port to define periods of time in which it will not attempt to acquire a
supplicant. The quiet period is the period for which the authenticator does not attempt to
acquire a supplicant after a failed authentication exchange with the supplicant. The quiet
period must be a number in the range of 0 and 65535. A quiet period value of 0 means that
the authenticator state machine will never acquire a supplicant. The default value is 60.
Changing the value will not change the configuration until the Submit button is pressed.

Transmit Period

- This input field allows the user to configure the transmit period for the

selected port. The transmit period is the value, in seconds, of the timer used by the
authenticator state machine on the specified port to determine when to send an EAPOL

Advertising