Accessing the Management Interface Troubleshooting and Tips

Intelligent Blade Panel Module

287

10.2 Accessing the Management Interface

You can access the management interface for the IBP from anywhere within the attached
network using Telnet, a Web browser, or any SNMP-based network management software. If
you are having trouble accessing the management interface, then refer to the troubleshooting
information displayed in the following table.

Symptom

Action

Cannot connect to the
IBP using Telnet, Web
browser, or SNMP
software

• Be sure you have configured the agent with a valid IP address,

subnet mask and default gateway.

• If you are trying to connect to the agent via the IP address for a

tagged VLAN group, your management station must include the
appropriate tag in its transmitted frames.

• Check that you have a valid network connection to the IBP

and that the port you are using has not been disabled.

• Check network cabling between the management station and the

IBP.

• If you cannot connect using Telnet, there may already be four

active sessions. Try connecting again at a later time.

Cannot access the
on-board

configuration program
via

a

serial

port

connection

• Be sure you have set the terminal emulator program to VT100

compatible, 8 data bits, 1 stop bit, no parity, and 19200 bps.

• Check that the null-modem serial cable conforms to the pin-out

connections provided in the Operating Manual for the server.

Forgot or lost the
password

• Restore the “Factory_Default_Config.cfg” file with the “boot

system” command described on page 134.