2-2. operation system, 2-3. monitor system – Sony SIR-3400H Benutzerhandbuch
Seite 151

SIR-3400H / SIR-3032i / SIR-3032W
(E)
22-5
Input
:
Connector
BNC
x 32
Input format
Direct
IEPE
Transmission format
Single-ended, Differential
Single-ended
Sensor power
—
24 V/4 mA
supply
(Voltage drop of constant-current
circuit is 2 V)
Input coupling
DC, AC (0.5 Hz)
AC (0.5 Hz)
Input range
±0.1, ±0.2, ±0.5, ±1, ±2, ±5, ±10 Vpk
Input DC offset
±100 % 1 % step
—
(During coupling DC operation
only)
Input impedance
100 k
Z
Voltage-resistance
±50 Vpk
TEDS (IEEE1451
.4) —
Support
DIRECT input — Voltage input
IEPE input — Sensor input with built-in preliminary amplifier
Output
:
Connector
BNC
x 33 (Including 1 CH monitor in unit)
Transmission format
Single-ended
Output level
±1, ±2, ±5, Variable (±0.5 to ±5) Vpk
Output impedance
50
Z
Adaptive load
Above 10 k
Z
22-2-2. Operation System
MONITOR
: Monitored channel selectable
ID No.
: Unit ID number setting (1 to 4)
22-2-3. Monitor System
Moni/ID
: Displays Monitored channel/Unit ID number
Level LED
: Simultaneous indication for 1 to 32 channels, unidirectional indicator
Power source
: POWER
Monitor
: MONITOR CH is displayed : LED on
Unit ID is displayed
: LED off
INPUT
: IEPE input
22. Specifications