2-4. power supply system, 2-5. dimensions and mass, 2-6. operating environment – Sony SIR-3400H Benutzerhandbuch

Seite 152

Advertising
background image

22-6

(E)

SIR-3400H / SIR-3032i / SIR-3032W

22-2-4. Power Supply System

AC (g)

Voltage (rated)

: 100/120 V

220/240 V

Voltage (allowable range)

: 90 to 132 V

198 to 250 V

Band (rated)

: 50/60 Hz

50/60 Hz

Band (allowable range)

: 47 to 66/440 Hz

47 to 66 Hz

Power consumption

: 215 VA

215 VA

Standby power consumption : 50 VA

55 VA

DC (

)

Voltage (rated)

: 12 V

Voltage (allowable range)

: 11 to 30 V

Current consumption

: 15 to 5.5 A

Battery

Nickel-metal- hydride battery: 24 V 1.1 Ah
Power supply priority

: AC > DC > internal backup battery (UPS function)

22-2-5. Dimensions and Mass

Dimensions

: 449 (W)

x 88 (H) x 305 (D) mm (excluding projections)

Mass

: Approx. 7.5 kg

22-2-6. Operating Environment

Recommended temperature/humidity for operation : 0 to 40

dC, 20 to 80 % RH (non-condensating)

(Be sure to warm up the recorder if it is operated under
5

dC.)

Recommended temperature/humidity for storage

:

_10 to 50 dC, 10 to 90 % RH (non-condensating)

Recommended pressure for specifications

: 660 to 1060 hPa (Equivalent to the altitude of about

3000 m to

_400 m)

Operating position

: Horizontal (front panel facing forwards)

Vibration resistance

: 14.7 m/s

2

5 Hz to 200 Hz (horizontal position)

Shock resistance

: 392 m/s

2

, 11 ms (while stored)

Polution degree

: II

Over voltage categoly

: II

22. Specifications

Advertising