Maintenance and Care

Version 06/05

• After a while the indication moves back to the

current time.

3.2.3

Bleeding the Metering Pump

The metering pump must be bled when the pump
has drawn in air (e. g., because the metering con-
tainer is completely empty).

• The system stops; the “Motor/hard water“ mal-

function indication is shown in the display.

• Fill the empty metering container and mix the

chemicals according to Section 3.2.6.

• Unscrew the bleeding screw (34) by one turn.

• Press the MANUAL pushbutton (33) until the

medium flows without bubbles through the
bleeding line (35) back into the container.

• Screw in the bleeding screw again.

• On the control panel, acknowledge the mal-

function indication with the RETURN key but-
ton (36); the system starts.

3.2.4

Replacing the Fine Filter

Check the pressure difference at manometers (15)
and (16). Replace the filter insert when over 0.8 bar:
• Switch off the equipment at the main switch (20).
• Stop the untreated water supply.

• Place a bucket under the untreated water drain

cock (37) and open the cock.

• Wait until no more water emerges out of the

cock, then shut the cock again.

• Attach the filter wrench (41) to the filter bowl

(40) and screw off the filter bowl.

• Remove the filter insert (38) from the filter bowl

and replace with a new one.

i

This malfunction indication is shown in-
dependent of which metering container
is empty.

31

32

34

33

35

i

The filter bowl is still filled with water.

ESC

production / production
produccion / produzione

fault / default
error / guasto

disinfection / nettoyage
desinfeccion / disinfezione
reject / rejet
evacuation / evacuatione

regeneration / regeneration
regeneracion / rigenerazione
tank full / stockage plein
deposito lleno / serbatoto pieno

RO 1000

36

37

41

40

39

38

16

15

Advertising