Karcher FS 2000 Benutzerhandbuch

Seite 12

Advertising
background image

English

FS 2000

26

Insert cap in pressure vessel

opening

Fit cap

Warning:

Sealing ring must make uniform

contact with pressure vessel

opening!

Flip over fastener and press down

as far as it will go

Insert pressure vessel in unit

Secure bracket

Connect air hose

Flushing pressure vessel
Warning:

Chemical reaction hazard!

Unit must be thoroughly cleaned of

all residue before switching from

acid to alkaline cleaning agents!

Pressure vessel will otherwise be

damaged by pitting.

Stopping machine

Dissipate pressure

Drain pressure vessel

Fill pressure vessel with water

Warning:

Water temperature

max. 50 °C

Volume

max. 20 l

Close pressure vessel

Close air supply valve

(position across direction of flow)

Turn control valve anti-clockwise

Insert power plug

Set ON/OFF switch to „I“

Actuate hand gun until fluid in

pressure vessel has been used up

CARE

Stopping machine

Dissipate pressure

Drain pressure vessel

Flushing pressure vessel

Only use a damp cloth for cleaning

the cleaner

Wipe over with clean, dry cloth

Do not use chemical cleaning

agents!

Rinse out pressure vessel with

water and leave standing open to

dry

Danger of poisoning!

Never blow into clogged nozzles

or valves

Take utmost care to avoid water

pollution

Clean fan jet nozzle by hand/with

tooth brush

Advertising