Filling with cleaning
agent/disinfectant
∗
Use is only to be made of
approved products (refer to
cleaning agent overview)
∗
Never fill with solvent
(petrol, acetone, thinner etc.)!
∗
Avoid contact with eyes and
skin
∗
Observe cleaning
agent/disinfectant manufacturer's
notes on safety and handling
∗
Always wear protective clothing,
mask, protective goggles, rubber
boots and rubber gloves
Warning:
Chemical reaction hazard!
Unit must be thoroughly cleaned of
all residue before switching from
acid to alkaline cleaning agents!
Pressure vessel will otherwise be
damaged by pitting.
An approved, individual range of
cleaning agents and disinfectants
is available from Kärcher.
Your dealer will be pleased to
advise you.
Open air supply valve
Open safety valve and dissipate
pressure.
Open fastener on pressure vessel
Cap is released inwards
Make sure seal does not drop
into vessel.
Take out cap
Heed cleaning agent/disinfectant
manufacturer's instructions on
dilution/mixing!
Warning:
Maximum total filling capacity: 20 l
Residual volume in pressure vessel
is required as air cushion.