21

Filling with cleaning

agent/disinfectant

Use is only to be made of

approved products (refer to

cleaning agent overview)

Never fill with solvent

(petrol, acetone, thinner etc.)!

Avoid contact with eyes and

skin

Observe cleaning

agent/disinfectant manufacturer's

notes on safety and handling

Always wear protective clothing,

mask, protective goggles, rubber

boots and rubber gloves

Warning:

Chemical reaction hazard!

Unit must be thoroughly cleaned of

all residue before switching from

acid to alkaline cleaning agents!

Pressure vessel will otherwise be

damaged by pitting.

An approved, individual range of

cleaning agents and disinfectants

is available from Kärcher.

Your dealer will be pleased to

advise you.

Open air supply valve

Open safety valve and dissipate

pressure.

Open fastener on pressure vessel

Cap is released inwards

Make sure seal does not drop

into vessel.

Take out cap

Heed cleaning agent/disinfectant

manufacturer's instructions on

dilution/mixing!

Warning:

Maximum total filling capacity: 20 l

Residual volume in pressure vessel

is required as air cushion.