Warning:

Chemical reaction hazard!

Unit must be thoroughly cleaned of

all residue before switching from

acid to alkaline cleaning agents!

Pressure vessel will otherwise be

damaged by pitting.

−

Flushing pressure vessel

(refer to Flushing pressure vessel)

Note:

Pressure = 5,5 bar:

Compressor cuts out

Pressure = 4 bar:

Compressor cuts in again

Shampooing/cleaning

−

Mounting shampoo nozzle

(pre-assembled, part of scope of

delivery)

Open air supply valve

(position in direction of flow)

Give control valve 2,5 anti-clockwise

turns

Set ON/OFF switch to „I“

Allow operating pressure to build up

(compressor cuts out)

Actuate hand gun

Note:

Set shampooing mode at control

valve:

Turning anti-clockwise =

Shampoo becomes moister

Turning clockwise =

Shampoo becomes drier
Kärcher Tip:

A longer exposure time makes

severe, stubborn soiling easier to

remove.

This applies particularly to cleaning

of exhaust air ducts, corners and

awkwardly shaped surfaces.

Spraying/disinfection

−

Mounting fan-jet nozzle

(accessory, not part of scope of

delivery)

Mount nozzle

−

Stopping machine

−

Dissipate pressure

−

Fit nozzle with cap nut

Close air supply valve

(position across direction of flow)

Set ON/OFF switch to „I“

Allow operating pressure to build up

(compressor cuts out)

Actuate hand gun

Note:

Use control valve to set delivery

rate:

Turning anti-clockwise =

Higher delivery rate

Turning clockwise =

Lower delivery rate
Kärcher Tip:

Pay careful attention to instructions

of disinfectant manufacturer.

Advertising