6. Spare parts

When ordering spare parts, please quote the Ident. No. of the chuck and the item number or designation of the desired part
(see page 2). -- The Ident. No. will be found on the face of the chuck.

5. Maintenance

The level of maintenance of the clamping device determines
its functionality, clamping force, accuracy and service life.
Regular maintenance consists of charging the grease nip-
ples (see illustration) with approx. 0.5 cm

3

grease approxi-

mately every 8 operating hours. A non--acidic, viscous
grease with MoS

2

additive should be used for this purpose.

We recommend our F90* grease in this respect.
Several no--load clamping strokes should be completed
after lubricating to distribute the grease applied evenly.
The guides for the 3 wedge bars and 3 clamping jaws are
supplied with lubricant via the grease nipples.

Blowing out:

Never blow into the jaw guides or guide slots with air.

Preventing maintenance work:

Check-list

Period

Procedure

Possibility of error

Checking clamp. force

every 6 months

Clamping force measuring

wear of the sealings in the cylinder

system EDS**

lack of lubrication

Wear control of the

weekly

visually

loss of torque

clamping set

loss of accuracy

Mounting check of the

weekly

check screw connection

loss of torque

clamping set parts

loss of accuracy

*

Recommended grease F90

:

Id.-Nr.:

100-g-tube

630869

1000-g-case

619989

**

Recommended clamping force measuring system EDS

:

Id.-Nr.:

EDS 50 compl.

161425

EDS 100 compl.

161426

EDS 50/100 compl.

161427

19