6. Spare parts
When ordering spare parts, please quote the Ident. No. of the chuck and the item number or designation of the desired part
(see page 2). -- The Ident. No. will be found on the face of the chuck.
5. Maintenance
The level of maintenance of the clamping device determines
its functionality, clamping force, accuracy and service life.
Regular maintenance consists of charging the grease nip-
ples (see illustration) with approx. 0.5 cm
3
grease approxi-
mately every 8 operating hours. A non--acidic, viscous
grease with MoS
2
additive should be used for this purpose.
We recommend our F90* grease in this respect.
Several no--load clamping strokes should be completed
after lubricating to distribute the grease applied evenly.
The guides for the 3 wedge bars and 3 clamping jaws are
supplied with lubricant via the grease nipples.
Blowing out:
Never blow into the jaw guides or guide slots with air.
Preventing maintenance work:
Check-list
Period
Procedure
Possibility of error
Checking clamp. force
every 6 months
Clamping force measuring
wear of the sealings in the cylinder
system EDS**
lack of lubrication
Wear control of the
weekly
visually
loss of torque
clamping set
loss of accuracy
Mounting check of the
weekly
check screw connection
loss of torque
clamping set parts
loss of accuracy
*
Recommended grease F90
:
Id.-Nr.:
100-g-tube
630869
1000-g-case
619989
**
Recommended clamping force measuring system EDS
:
Id.-Nr.:
EDS 50 compl.
161425
EDS 100 compl.
161426
EDS 50/100 compl.
161427
19