Checking leds – Allied Telesis x900 Series Switch Benutzerhandbuch

Seite 13

Advertising
background image

Installation and Safety Guide

13

Checking LEDs

Table 1 below describes how LEDs on the switch report faults and operational
activities.

Table 2 on page 14

describes how LEDs on power supply units and fan-only

modules report faults and operational activities.

LEDs for Ethernet ports and Small Form Factor Pluggable (SFP) ports are
described in the Hardware Reference.

Table 1: System LEDs

LED

State

Description

PSU 1

Green

PSU 1 is installed and supplying power to the switch.
The voltage output is within specification.

Red

PSU 1 is installed in the switch and has exceeded its
recommended temperature threshold of 75º C
(167º F), or the fan has failed.

A FOM is installed in the switch and has failed.

The bay is empty. Applies to AT-8948, AT-9924T/4SP,
and AT-9924Ts switches since they require a FOM
when only one PSU is installed.

Off

A FOM is installed and operating at an acceptable speed.

For AT-9924T and x900-48FE switches, a blanking panel
is installed.

PSU 2

Green

PSU 2 is installed and supplying power to the switch.
The voltage output is within specification.

Red

PSU 2 is installed in the switch and has exceeded its
recommended temperature threshold of 75º C
(167º F), or the fan has failed.

A FOM is installed in the switch and has failed.

The bay is empty. Applies to AT-8948, AT-9924T/4SP,
and AT-9924Ts switches since they require a FOM
when only one PSU is installed.

Off

A FOM is installed and operating at an acceptable speed.

For x900-48FE switches, a blanking panel is installed.

Advertising