Allied Telesis x900 Series Switch Benutzerhandbuch
Seite 14

x900 Series Switch
14
Fault
Red
The switch or management software is malfunctioning.
1 Flash
One or more heatsink fans has failed or is operating
below the recommended speed.
3 Flashes
For AT-9900, AT-9924Ts, and x900-24X switches, the
ability to monitor temperature and fans has failed, and
it cannot report whether they are in the supported
ranges. After flashing three times, the LED stops briefly,
then repeats the sequence.
6 Flashes
The switch’s temperature has exceeded the
recommended threshold. After flashing six times, the
LED stops briefly, then repeats the sequence.
Slow
flashing at
startup
The SDRAM (DIMM) has not been detected. Not
applicable to AT-9924Ts or x900-24X switches.
Rapid
flashing at
startup
The SDRAM (DIMM) is not compatible with the switch.
Not applicable to AT-9924Ts or x900-24X switches.
CF
Green
flashing
The CompactFlash memory card is active and should
not be ejected. The card can be safely ejected when the
LED remains off. Valid for AT-8948, x900-48FE, and
AT-9900 switches.
SD
Green
flashing
The Secure Digital memory card is active and should
not be ejected. The card can be safely ejected when the
LED remains off. Valid for AT-9924Ts and x900-24X
switches.
Table 2: LEDs on the power supply unit and fan-only module
LED
State
Description
Fault
Red
The temperature on the PSU has exceeded the limit of
75º C (167º F), or the fan failed.
PWR
Green
A PSU is installed in the switch and is receiving power. A
FOM does not have this LED.
Table 1: System LEDs (Continued)
LED
State
Description