Allied Telesis x900 Series Switch Benutzerhandbuch

Seite 14

Advertising
background image

x900 Series Switch

14

Fault

Red

The switch or management software is malfunctioning.

1 Flash

One or more heatsink fans has failed or is operating
below the recommended speed.

3 Flashes

For AT-9900, AT-9924Ts, and x900-24X switches, the
ability to monitor temperature and fans has failed, and
it cannot report whether they are in the supported
ranges. After flashing three times, the LED stops briefly,
then repeats the sequence.

6 Flashes

The switch’s temperature has exceeded the
recommended threshold. After flashing six times, the
LED stops briefly, then repeats the sequence.

Slow
flashing at
startup

The SDRAM (DIMM) has not been detected. Not
applicable to AT-9924Ts or x900-24X switches.

Rapid
flashing at
startup

The SDRAM (DIMM) is not compatible with the switch.
Not applicable to AT-9924Ts or x900-24X switches.

CF

Green
flashing

The CompactFlash memory card is active and should
not be ejected. The card can be safely ejected when the
LED remains off. Valid for AT-8948, x900-48FE, and
AT-9900 switches.

SD

Green
flashing

The Secure Digital memory card is active and should
not be ejected. The card can be safely ejected when the
LED remains off. Valid for AT-9924Ts and x900-24X
switches.

Table 2: LEDs on the power supply unit and fan-only module

LED

State

Description

Fault

Red

The temperature on the PSU has exceeded the limit of
75º C (167º F), or the fan failed.

PWR

Green

A PSU is installed in the switch and is receiving power. A
FOM does not have this LED.

Table 1: System LEDs (Continued)

LED

State

Description