AT-200 Single Port Transceiver

5

11. To install the transceiver, align the opening on the transceiver body so that

the diagnostic LEDs are facing you. (The transceiver is reversible front to
back.) Gently guide the tap body into the transceiver opening so that the
probe post and the two braid terminator posts are aligned with the three
gold-colored circuit board contacts. Then slide the tap assembly fully into
the slot.

12. Secure the tap body to transceiver with the two panhead screws.

Replacement probe assembly and braid terminators are available as

tool kit AT-060-K.

13. Be sure the cable is terminated at both ends. Figure 3 shows a terminator

installed at one end of a thicknet segment.

Figure 3:

50

Terminator for Thicknet Segment

Thick Ethernet installation with coaxial N-series tap (for model
AT-208)

Before installing the AT-208 Single Port Transceiver, check to see that the
transceiver package contents are complete. If any of the following items are
missing or damaged, contact your sales representative.

AT-200 Series Single Port Transceiver with AT-08 tap

Manual

Warranty card

No assembly of the transceiver is required. It comes with the tap body factory
installed. See Figure 4.

Note

Thicknet
terminator

Cable